H07RN-F 3G95 cut to length

Descrição

Descrição

Padrões

  • Product
    EN 50525-2-21; HD 22.4; HD 516; IEC 60245-4 type 66; NF C32-102-4

Application

H07RN-F flexible cable is intended for installations with moving equipments, electric appliances and for building sites also for motors in lifting  appliances -machine tools, etc ... The cable may be rated up to 0,6/1 kV where the installation has built-in protection.

This range of cables is recommended in dry, damp or wet workshops, indoor and outdoor, for example in explosive atmosphere(as ATEX) according to regulation of the country and with some additional  recommendations and  also for industrial devices  and agricultures workshops ...

This cable can be used in refrigerating installations.

Installation

Conductors laid up 

Assembled conductors.

Nota

Max continuous operating conductor temperature in normal use :

+60°C   (in every case of mobile installation)

+85°C (in fixed and protected installation)

+200°C ( in short circuit )

Permissible current rating is measured for an ambient temperature of 30°C and a maximum operating and conductor temperature of 60°C . For other temperature please refer to correction factors .

European Directive  RoHS :  Compliant

SY+ :  French  directive for  lead free materials in materials.

Características

Características

Construction characteristics

Construction characteristics

Conductor flexibility
Flexible class 5
Conductor material
Bare annealed copper stranded
Conductor shape
Circular
Insulation
Cross-linked synthetic elastomer type EI 4
Lead free
Yes
Outer sheath
Cross-linked synthetic elastomer type EM 2
Sheath colour
Black
With Green/Yellow core
Yes

Características dimensionais

Características dimensionais

Conductor cross-section
95 mm²
Number of cores
3
Approximate weight
4170 kg/km
Maximum outer diameter
54,0 mm
Minimum outer diameter
43,3 mm

Electrical characteristics

Electrical characteristics

Max. linear resistance, phase conductor
0,206 Ohm/km
Permissible current rating in open air
320 A
Phase reactance 50 Hz - trefoil formation
- Ohm/km
Rated Voltage Uo/U (Um)
450/750 V
Voltage drop, single phase
0,5 V/A.km

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Very good
Cable flexibility
Flexible

Usage characteristics

Usage characteristics

Packaging
Cut to length
Length
- m
Chemical resistance
Accidental
Water proof
Good
Flame retardant
IEC 60332-1-2
Max. conductor temperature in service
85 °C
Minimum dynamic operating bending radius
- mm
Minimum static operating bending radius
- mm
Oil resistance
Yes
Operating temperature, range
-25 ... 55 °C
RoHS compliant
Yes
Short-circuit max. conductor temperature
200 °C
Weather resistance
Very good

Recursos

Recursos

Informações de venda e entrega

Marking
USE <'HAR> H07RN-F N (x or G) S mm²
N = number of cores

G = with Green-Yellow
x = without Green-Yellow
S = section in mm²

Declaração de desempenho

  • Declaração de desempenho nº : 1000023-FRBH
  • Data de certificação : 15/03/22
  • Avaliação e Verificação da Constância do Desempenho) : System 3
  • Corpo notificado : NB 1812
  • Desempenho declarado : Eca

Entre em contato conosco

Tópicos sobre os quais você deseja obter mais informações

Campos obrigatórios*

Por favor, verifique sua entrada e tente novamente

Um endereço de e-mail deve conter um único @

Protetor de dados pessoais

Você tem o direito de se opor ao processamento de seus dados pessoais e/ou seu uso para marketing direto ou fins comerciais

Obrigado!

Obrigado por entrar em contato conosco. Retornaremos em breve.

Erro

Aconteceu um erro. Por favor, tente novamente mais tarde

Fechar